Optional extras                                 Real Picture Show

"More than 300 different Optional extras'

 

  AA =       Dry actuator (sealed plunger)                             MA =      Mechanical position indicator

     AF =       ANSI flanged 150 lbs.                                     NB =       NO+BF, Normally open construction and

     AS =       Welding joints                                                             free of brass & bronze

 

     BF     =     Free of brass & bronze                                   NE =       NO+ EH, Normally open construction with

     BH     =     Free of brass & bronze and manual                                 position indicator

                      operation                                                    NF =       NO+OF, Normally open and oxygen construction

     CN     =     Nickel plated brass                                       NG =       NPT connection ports

 

     CM=       CN+ HA, Nickel plated brass and                      NL =       NO+TM+HA, Normallyopen and hightemp (+130'C)

                   manual operation                                                          construction with manual operation

     CO =       CN+ NO, Nickel plated brass and                      NM=       NO+ MA, Normally open construction with

                   normally open construction                                             mechanical position indicator

     CR =       CN+ SR, Nickel plated brass and                      NO =       Normally open construction

                   variable close muting

     EE =        2 electronic position indicators in                      NS =       NO+SR, Normally open construction

                   external connection box                                                  variable close muting

     EG =       I electronic position indicator in                        NT =       NO +TM, Normally open and high temp (+ 1 300C)

                   external connection box                                                  construction

     EH =          I electronic position indicator                         NW =      NO +TH, Normally open and high temp (+ 1 800C)

                   (reed contact)                                                                construction

       EJ =        2 electronic position indicators                       OA =       Complete valve system without body

                      (reed contacts)

       EL =       Electronic device for increase of pick up              OE =     Complete valve system without actuator

                      power (only available in 230V 50-6OHz)                           (coil, tube, plunger)

       EP =       Mechanical position indicator                           OF      =  Oxygen construcflon

                      (visual indication)                                           SR      =  Variable close muting

       EX =       Ex proof (electronic) position indicator               TA      =  TH +TA, High temp (+ 1 800C) construction with

                      Ex-s-G5                                                                       manual operation

 

       FL =       Flange end connection                                     TB       =        TM+ HA, High temp (+ I 30'C) construction with

                      ports                                                                                  manual operation

       HA =       Manual operation (override)                              TG       =        TM+ EH, High temp (+ I 300C) construction with

                                                                                                              position indicator

       HE =       HA+ EH, Manual operation with 1                    TH       =        High temp (+ 1 800C) construction

                      electronic position indicator

       HN =       Manual operation and normally open                  TM       =        High temp (+ 1 300C) construction

                      construction

       HO =       HA+OF, Manual operation and oxygen              UN       =        3/2 way universal construction

                      construction                                                                        (each inlet can be used as 'p")

       HS =       HA+SR, Manual operation and                         VD       =        Vacuum and pressure construction

                      variable close muting                                      VU       =        Vacuum construction

       HV =       High viscosity construction                              VW      =          silicon free assembly (automobile industry)

 

       IA      =        Inside / outside threading

       ID      =        Protection cap for outside mounting

                          applications

       IH      =        [A+ HA, Inside / outside threading and

                          manual operation

       IN      =        IA+ NO, Inside / outside threading and

                          normally open construction

       IS      =        Protection (covered coil) for damp

                          surroundings (IP67)